0
Unable to connect to host 127.0.0.1 on port 7055 after 45000 ms. Firefox console output

Solved 1 Answers 93 Views
I am trying to execute my test, I am getting below error.

org.openqa.selenium.firefox.NotConnectedException: Unable to connect to host 127.0.0.1 on port 7055 after 45000 ms. Firefox console output:

    at org.openqa.selenium.firefox.internal.NewProfileExtensionConnection.start(NewProfileExtensionConnection.java:113)
    at org.openqa.selenium.firefox.FirefoxDriver.startClient(FirefoxDriver.java:271)
    at org.openqa.selenium.remote.RemoteWebDriver.<init>(RemoteWebDriver.java:119)
    at org.openqa.selenium.firefox.FirefoxDriver.<init>(FirefoxDriver.java:216)
    at org.openqa.selenium.firefox.FirefoxDriver.<init>(FirefoxDriver.java:211)
    at org.openqa.selenium.firefox.FirefoxDriver.<init>(FirefoxDriver.java:207)
    at org.openqa.selenium.firefox.FirefoxDriver.<init>(FirefoxDriver.java:120)
    at in.mayurshah.base.xRemoteWebDriver.getInstance(xRemoteWebDriver.java:53)
    at in.mayurshah.base.BaseActions.beforeTest(BaseActions.java:56)
    at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
    at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:62)
    at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43)
    at java.lang.reflect.Method.invoke(Method.java:498)
    at org.testng.internal.MethodInvocationHelper.invokeMethod(MethodInvocationHelper.java:80)
    at org.testng.internal.Invoker.invokeConfigurationMethod(Invoker.java:551)
    at org.testng.internal.Invoker.invokeConfigurations(Invoker.java:213)
    at org.testng.internal.Invoker.invokeMethod(Invoker.java:639)
    at org.testng.internal.Invoker.invokeTestMethod(Invoker.java:893)
    at org.testng.internal.Invoker.invokeTestMethods(Invoker.java:1218)
    at org.testng.internal.TestMethodWorker.invokeTestMethods(TestMethodWorker.java:127)
    at org.testng.internal.TestMethodWorker.run(TestMethodWorker.java:111)
    at org.testng.TestRunner.privateRun(TestRunner.java:758)
    at org.testng.TestRunner.run(TestRunner.java:613)
    at org.testng.SuiteRunner.runTest(SuiteRunner.java:334)
    at org.testng.SuiteRunner.access$000(SuiteRunner.java:37)
    at org.testng.SuiteRunner$SuiteWorker.run(SuiteRunner.java:368)
    at org.testng.internal.thread.ThreadUtil$2.call(ThreadUtil.java:64)
    at java.util.concurrent.FutureTask.run(FutureTask.java:266)
    at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1142)
    at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:617)
    at java.lang.Thread.run(Thread.java:748)

org.openqa.selenium.WebDriverException: Failed to connect to binary FirefoxBinary(C:\Program Files (x86)\Mozilla Firefox\firefox.exe) on port 7055; process output follows:

1 Answer

1
Best answer
The problem is with your selenium driver version.

Either you need to upgrade your selenium library/server with Gecko driver or downgrade your Firefox browser to version 45.
answered May 9 by anonymous
selected May 9 by SunilBhaskar